3Par Cli Software

  

Ecosystem. No additional infrastructure services, hardware, or software is required to optimize for performance and reliability. HP 3PAR StoreServs base product. Free HPE storage performance monitoring 3. PAR XP7 MSA P2. 00. FK-aDrnGVM/maxresdefault.jpg' alt='3Par Cli Software' title='3Par Cli Software' />HPE XP7 is re branded Hitachi VSP G therefore install procedure is same as for it. In case of usage of Virtual Appliance. Use local account lpar. STOR2. RRD on the virtual appliance. Use homestor. 2rrdstor. The program uses two Hitachi HPE APIs. Last week I got a call from a customer. The customer has tried to deploy new Citrix XenApp servers, and because the VMware template was a bit outdated, he tried to. The licensing for 3 Par is essentially spindle based, you can read more about it on pages 4647 of the 3Par Software QuickSpecs document httpwww8. AutoConf iSCSI creates the iSCSI configuration following best practices for ESXi 4, 5 and 6 new in version 2. It currently works for HPE 3PAR StoreServ, HPE MSA. List of well known, registered, and dynamicprivate ports. Since monday Im helping a customer to put two HP 3PAR StoreServ 7200c into operation. Both StoreServs came factoryinstalled with 3PAR OS 3. MU3, which is. 3Par Cli SoftwareYou have to install both of them. Command Control Interface CCIHitachi HPE Export Tool. You might also look into very detaily described installation procedure on www. Note that Virtual Storage Machines VSM feature is not supported by the tool. Installation of CCI. Allow communication from STOR2. Par Cli Software' title='3Par Cli Software' />RRD host to all storages on TCP ports 1. UDP 3. 10. 01, 3. Test open ports for TCP protocols UDP ports cannot be tested via that. Connection to 1. Connection to 1. Create user stor. View and Download HP 3PAR StoreServ 7200 2node administrators manual online. HP 3PAR Command Line Interface Administrators Manual HP 3PAR OS 3. QR48296525. Contact Us. If you notice problems with the data in the vCG, please let us know. Please note The team monitoring your feedback cannot respond to the questions about. Free HPE storage performance and capacity monitoring 3PAR XP7 MSA P2000. Obtain CCI installation package from your HPE representatives. Install it from. HS0. V cdrfs o ro m mnt. HORCM. Install from CD. XXXX where XXXX IO device with install media. HORCM HORCM. Execute the CCI installation command. Verify installation of the proper version using the raidqry command. Model RAID ManagerHP UX. Ver Rev 0. 1 2. Usage raidqry options. Assure that everything is executable and writeable by stor. This is a must Under root identification execute this. HORCMetcUSEOLDIOCT. HORCM. chown R stor. HORCMlog HORCM. HORCMusr. HORCM HORCMusrbin HORCMusrbinHORCMlog HORCMetchorcmgr HORCMetconf HORCM. HORCM. uds Configuration of CCICCI communication with storage can be done either via LAN it is something described below or via command device SAN attached volume from the storage. When you have many storages in place 4. LAN communication might not be reliable enough. CCI command device configuration procedure Each storage must have its own config file etchorcm. XX. conf Check if local ports 1. IP 1. 92. 1. 68. 1. UDPUse storage node IP. SVP IP must be used in etcstorage list. IPCMD 1. 92. 1. 68. IP 1. 92. 1. 68. 1. IPCMD 1. 92. 1. 68. Start it under stor. Use lpar. 2rrd account on the Virtual Appliance. This starts HORM instance 1 etchorcm. HORCMusrbinhorcmstart. Start HORM instance 1 2 etchorcm. HORCMusrbinhorcmstart. Check if they are running. Feb 2. 6 0 0. 3 horcmd0. Feb 2. 6 0 0. 9 horcmd0. Place it into operating system startstop scripts. HORCMusrbinhorcmstart. HORCMusrbinhorcmshutdown. Installation of Export Tool. It is typically located on a CD that comes packaged with the Service Processor on the HPE XP7 Array. The Export Tool can also be obtained by contacting HPE support. CD location Tools. PackExport. Tool. There is a new Export Tool build for each release of the firmware. Unless you make sure all of the storages are running on the same firmware version then you will need to obtain the appropriate version of the Export Tool to meet the firmware version you are running at the site. Find our firmware release of your storage 8. I1 Under stor. 2rrd accountI1. I1. No Group Hostname HORCMver Uid Serial Microver CacheMB. I1. Install each version of the Export Tool into separate directory named as firmware of your storage just 6 numbers like in this example firmware 8. R stor. 2rrd opthds. Might work that higher Export Tool version works even with lower storage firmware like in that example Export Tool 8. In this case you do not need to install older Export Tool, just make a symlink. Directory opthds is optional, it is configurable in homestor. VSPCLIDIRopthds. The HPE Performance Monitor License must exist for each array and monitoring must be enabled. Storage configuration example. Allow monitoring of CU and WWNSTOR2. RRD storage configuration All actions below under stor. Virtual Appliance. Configure Export Tool installation directory in homestor. Create user stor. Configure storages in etcstorage list. Uncomment remove the hash example line and adjust it. Use storage SVP IP here CCI above uses storage node IP. Hitachi VSP G HPE XP7. Storage Alias VSPG IP addresshostname storage user password etchorcm. VOLUMEAGGDATALIM VOLUMEAGGIOLIM SAMPLERATEMINS. XP7 alias VSPG 1. KT4m. XVI9. N0. BUPj. Zd. VQo etchorcm. XP7 0. 1 VSPG 1. KT4m. XVI9. N0. BUPj. Zd. VQo etchorcm. Above shows storage with IP 1. GUI as XP7 0. 1Use encrypted password in storage line above. Encode password for storage authentication. Enter password. Re enter password. Copy the following string to the password field of the corresponding line in etcstorage list. KT4m. XVI9. N0. BUPj. Zd. VQo. Assure you have enough of disk space on the filesystem where is STOR2. RRD installed. Roughly you might count 2 3. GB per a storage it depends on number of volumes, 3. Calculate Pi. GB for 5. 00. 0 volumes. AIX. df h home Linux. Test the storage connectivity under stor. Obd Car Diagnostic Software S. STORAGE XP7 0. 1 VSPG. Schedule to run storage agent from stor. Virtual Appliance, it might already exist there. HPE XP7 use Hitachi VSPG scipt loadvspgperf. Assure there is already an entry with the GUI creation running once an hour in crontab. STOR2. RRD GUI just ONE entry of load. Let run the storage agent for 1. Go to the web GUI http lt your web server stor. Use Ctrl F5 to refresh the web browser cache.